  • IP 65 PROTECTION DEGREE
  • DOUBLE INSULATION
  • INSTALLATION EVEN ON FLAMMABLE SURFACES
  • BODY IN SELF-EXTINGUISHING POLYCARBONATE ACCORDING TO 94V-2 (UL 94)
  • INCANDESCENT WIRE 850C (I.E.C 695-2-1/C.E.I 50-11)
  • WORKING TEMPERATURE: 0-40C

INSTALLATION: Wall - Ceiling - Flush - False ceiling Hanging - Conduit

 
 

 
Domina ACTIVA
 
  • Luminaire providing both Maintained (M) and Non-Maintained (NM) emergency lighting
  • Fitted with the self-diagnosis device
  • Built in compliance with C.E.I EN 60598-2-22 Regulations
  • "Rest Mode" facility in compliance with C.E.I EN 60598-2-22 Regulations
  • Emergency operation inhibit with rest mode via Teleur remote control
  • Maintained remote inhibition by switch
  • Input 230V 50 Hz
  • Complete recharge in 12 hours for 1 h duration models
  • Ni-Cad batteries for high temperatures (NC version)
 
RILUX _ COD BAT DUR LH Lm Ml AFl AFl S.A. KG PK
DOMINA
ACTIVA
6/1NC
37801 4,8V
1,2Ah
Ni-CAD
1 G5 6 4,5 62   0,9 1/12
DOMINA
ACTIVA
6/3NC
37802 7,2V
1,2Ah
Ni-CAD
3 G5 6 4,5 58   0,98 1/12
DOMINA
ACTIVA
8/1NC
37805 4,8V
1,2Ah
Ni-CAD
1 G5 8 4,5 128   0,9 1/8
DOMINA
ACTIVA
8SA/1NC
37807 4,8V
1,2Ah
Ni-CAD
1 G5 8 4,5 171 268 0,94 1/8
DOMINA
ACTIVA
8/3NC
37806 9,6V
1,2Ah
Ni-CAD
3 G5 8 4,5 115   1,3 1/8
DOMINA
ACTIVA
8SA/3NC
37808 9,6V
1,2Ah
Ni-CAD
3 G5 8 4,5 118 186 1,35 1/8
DOMINA
ACTIVA
U11/1NC
37803 6,0V
1,2Ah
Ni-CAD
1 2G7 11 6 147   1 1/12
DOMINA
ACTIVA
U11/3NC
37804 6,0V
2,0Ah
Ni-CAD
3 2G7 11 6 147   1,2 1/12
DOMINA
ACTIVA
20/1NC
37811 4,8V
4,0Ah
Ni-CAD
1 G13 18 11,5 420   2,13 1/4
DOMINA
ACTIVA
20SA/1NC
37813 4,8V
4,0Ah
Ni-CAD
1 G13 18 11,5 420 525 2,24 1/4
DOMINA
ACTIVA
20/3NC
37812 6,0V
7,0Ah
Ni-CAD
3 G13 18 11 420   2,64 1/4
DOMINA
ACTIVA
20SA/3NC
37814 6,0V
7,0Ah
Ni-CAD
3 G13 18 11,5 420 525 2,75 1/4
DOMINA
ACTIVA
U24/1NC
37809 6,0V
4,0Ah
Ni-CAD
1 2G11 24 8 637   2,04 1/8
DOMINA
ACTIVA
U24SA/1NC
37810 6,0V
4,0Ah
Ni-CAD
1 2G11 24 8 653 674 2,39 1/8
 
Legend
COD = Code Ml = Mains load (VA)
BAT = Battery AFl = Average flux (Lm)
DUR = Duration AFl S.A. = Average FLUX S.A. (Lm)
LH = Lamp holder Kg = Weight (Kg)
Lm = Lamp (W) PK = Packing
*= Luminaire supplied without screen
 
Domina for DARDO system
 
 
  • Luminaire providing both Maintained (M) and Non-Maintained (NM) emergency lighting
  • Fitted with a self-diagnosis system controlled by a central position
  • Built in compliance with C.E.I EN 60598-2-22 Regulations
  • "Rest Mode" facility in compliance with C.E.I EN 60598-2-22 Regulations
  • Emergency operation inhibit with Rest Mode via DARDO Box 2 control unit
  • Input 230V 50 Hz
  • Complete recharge in 12 hours for 1 h duration models
  • Ni-CAD batteries for high temperatures
 
RILUX   COD BAT DUR LH Lm Ml AFl AFl S.A. KG PK
DOMINA
6/1NC
DAR
34081 4,8V
1,2Ah
Ni-CAD
1 G5 6 4,5 62   0,9 1/12
DOMINA
6/3NC
DAR
34082 7,2V
1,2Ah
Ni-CAD
3 G5 6 4,5 58   0,98 1/12
DOMINA
8/1NC
DAR
34085 4,8V
1,2Ah
Ni-CAD
1 G5 8 4,5 128   0,9 1/8
DOMINA
8SA/1NC
DAR
34087 4,8V
1,2Ah
Ni-CAD
1 G5 8 4,5 171 268 0,94 1/8
DOMINA
8/3NC
DAR
34086 9,6V
1,2Ah
Ni-CAD
3 G5 8 4,5 115   1,3 1/8
DOMINA
8SA/3NC
DAR
34088 9,6V
1,2Ah
Ni-CAD
3 G5 8 4,5 118 186 1,35 1/8
DOMINA
U11/1NC
DAR
34083 6,0V
1,2Ah
Ni-CAD
1 2G7 11 6 147   1 1/12
DOMINA
U11/3NC
DAR
34084 6,0V
2,0Ah
Ni-CAD
3 2G7 11 6 147   1,2 1/12
DOMINA
20/1NC
DAR
34091 4,8V
4,0Ah
Ni-CAD
1 G13 18 11,5 420   2,13 1/4
DOMINA
20SA/1NC
DAR
34093 4,8V
4,0Ah
Ni-CAD
1 G13 18 11,5 420 525 2,24 1/4
DOMINA
20/3NC
DAR
34092 6,0V
7,0Ah
Ni-CAD
3 G13 18 11 420   2,64 1/4
DOMINA
20SA/3NC
DAR
34094 6,0V
7,0Ah
Ni-CAD
3 G13 18 11,5 420 525 2,75 1/4
DOMINA
U24/1NC
DAR
34089 6,0V
4,0Ah
Ni-CAD
1 2G11 24 8 637   2,04 1/8
DOMINA
U24SA/1NC
DAR
34090 6,0V
4,0Ah
Ni-CAD
1 2G11 24 8 653 674 2,39 1/8
 
Legend
COD = Code Ml = Mains load (VA)
BAT = Battery AFl = Average flux (Lm)
DUR = Duration AFl S.A. = Average FLUX S.A. (Lm)
LH = Lamp holder Kg = Weight (Kg)
Lm = Lamp (W) PK = Packing
*= Luminaire supplied without screen
 
Domina 230
 
 
  • Emergency Luminaire fitted with electronic ballast at low consumption
  • Input 230V 50 Hz
 
RILUX _ CODE LAMP HOLDER LAMP
(W)
MAINS
LOAD
(VA)
Average
FLUX
(Lm)
WEIGHT
(Kg)
PACKING
DOMINA
8/230
40521 G5 8 10 255 0,830 1/8
DOMINA
20/230
40525 G13 18 35 500 1,390 1/4
DOMINA
U24/230
40523 2G11 24 34 642 0,930 1/8
 
Domina 230 for MCS system
 
 
  • Emergency Luminaire suitable for use with MCS system
  • Electronic ballast at low consumption
  • Input 230V 50 Hz
 
RILUX _ CODE LAMP HOLDER LAMP
(W)
MAINS
LOAD
(VA)
Average
FLUX
(Lm)
WEIGHT
(Kg)
PACKING
DOMINA
8/MCS
40522 G5 8 10 255 0,880 1/8
DOMINA
20/MCS
40526 G13 18 35 500 1,450 1/4
DOMINA
U24/MCS
40524 2G11 24 34 642 0,980 1/8
 
DOMINA 8

DOMINA 11
DOMINA 20
DOMINA U24
ISOLUX DIAGRAM DOMINA U24


The photometric data is approximated (average values); circle coefficients shall be taken into consideration for project calculation

 

 
 
WIRING DIAGRAMS FOR SELF-CONTAINED LUMINAIRES
 
 
DOMINA ACCESSORIES

 
LEGENDS
1 2 3
 
FLUSH-MOUNTING BOX PROTECTIVE GRILL
FALSE CEILING KIT
False ceiling mounting. Thanks to the new accessory (mounting brackets) it is possible to flush mount in traditional panelled false ceilings.
CONDUIT HANGING KIT
TELEUR    
 
ACCESSORIES
 
__ REF. CODE DIMENSIONS PACKING
LEGENDS
DOMINA 6-11W 1-2-3 50160 227x130 1/1
DOMINA 8-24W 1-2-3 50161 310x150 1/1
DOMINA 18W 1-2-3 50162 585x170 1/1
FALSE CEILING MOUNTING KIT
DOMINA   50663   1/6
PROTECTIVE GRILL
DOMINA 6/11W   50687   1/1
DOMINA 8/24W   50688   1/1
DOMINA 20W   50689   1/1
CONDUIT HANGING KIT
DOMINA
6-8-11-24W
  50685   1/1
DOMINA 20W   50686   1/1
CONDUIT HANGING KIT
DOMINA 6-11W   50655   25/25
DOMINA 8-24W   50656   20/20
REMOTE CONTROL
Teleur   50302   1/8
DIRECTIONAL INDICATING SIGNS
_ See section "directional indicating signs"
 


 

 

Home ] Up ] [OVA EMERGENCY LIGHTING] [ALTENBURGER] [ECLAT INVERTERS]

Send mail to anthony@eclat.co.za or mwtones@mweb.co.za with questions or comments about this web site.
Copyright 2005 ECLAT LIGHTING. Telephone: +27 11 868 3779 / +27 11 868 2578. Fax: +27 11 868 2578. Mobile: +27 82 562 9620.
Last modified: July, 2010.
COPYRIGHTS AND VARIOUS PATENTS SUBSIST IN THE PRODUCTS AND IN THE CONTENT OF THIS WEBSITE. UNAUTHORIZED DUPLICATION OF THE PRODUCTS AND OF THE CONTENT BY ANY MEANS IS STRICTLY PROHIBITED. UNAUTHORIZED DUPLICATION OF ANY PROPRIETY METHODS UTILIZED AND AS DESCRIBED IN THESE PRODUCTS AND THEIR RELATED DOCUMENTS, FOR ANY OTHER THAN OUR OWN INTENDED PURPOSES, IS STRICTLY PROHIBITED. THE CONTENT OF THIS WEBSITE, IT'S PRODUCTS AND IT'S DOCUMENTS ARE STRICTLY PRIVATE AND CONFIDENTIAL, AND SHALL UNDER NO CIRCUMSTANCES BE DISCLOSED TO ANY UNAUTHORIZED THIRD PARTIES, WITHOUT PRIOR AUTHORIZATION FROM THE WRITER. PERMISSION FOR SUCH DISCLOSURE AND/OR DUPLICATION OF THESE PRODUCTS AND THESE DOCUMENTS SHALL BE APPLIED FOR, AND CONFIRMED IN WRITING. FAILURE TO FOLLOW THE ABOVE, WILL RESULT IN CIVIL AND CRIMINAL PROSECUTION.

ALL ITEMS MARKED IN RED, ARE NOT YET VERIFIED / ARE FUTURE PROJECTS / ARE IN PROGRESS.

ALL PAGES SUBJECT TO CHANGE AND TECHNICAL ERROR.