ÉCLAT 3 EMERGENCY HIGH POWER LED LUMINAIRES AND GEARTRAYS

INDUSTRIAL BULKHEAD, ECL3 LED EMERGENCY GEARTRAY; EFFICIENT, ROBUST, RELIABLE AND EFFECTIVE


The ECL3 LED EMERGENCY GEARTRAY features pre-punched metalwork, fabricated from 1,0 mm Mild Steel. The Geartray sides are folded to ensure rigidity. This is then pre-treated, and Epoxy Powder Coated, to ensure a long Service Life and Durability. A white Geartray is offered as standard. The Inverter, Battery Packs and Standard Mains Control Gear, are held in place by M5 bright Plated Machine Screws.

The ECL3 LED EMERGENCY GEARTRAY houses all relevant and required Emergency Control Gear, and is constructed to accommodate a wide range of Emergency and Standard Mains Control Gear Options to suit Customer requirements.
On Maintained and on Electronic Mains Type Luminaires, Electronic Control Gear is made up of CE Approved Control Gear.

 

The ECL3 LED LED Utilizes ULTRA HIGH BRIGHTNESS LED’s (Light Emitting Diodes) as a Light Source. Lamp life is expected to be in the order of 100 000 hours. This equates to 11.4 years with the units running permanently.

 

The Light Output of the LED Modules combine to a total of 1600 Lumens. This is approximately equivalent in Light Output, to 2 x 18W Compact Fluorescent Lamps, or 2 x 80W 230V Standard Incandescent Lamps.

 

In terms of energy consumption, the LED's will absorb  a total of 160mA at 230V AC; the Incandescent Lamps would absorb 695mA at 230V AC. As can be seen, this is four times the efficiency.


The ECL3 LED EMERGENCY GEARTRAY features the robust range of ÉCLAT Inverters (See ÉCLAT INVERTERS,) which are suitable for all Fluorescent, Halogen, LED, and HID Lamps, with Light Outputs Ranging from as low as 10% to and up to 100%.

Time Durations from 0.5 Hour to 3 Hour can be accommodated on the ECL3 LED EMERGENCY GEARTRAY dependent on the Lamp Configuration and Wattage in use.

A choice of High Temperature Lead Acid Batteries are offered as Standard Equipment.

The Charger (which forms part of the Inverter Circuitry) and Inverter’s Electronic components are mounted within a 1-mm thick Extruded Aluminium housing, which also serves as a Heatsink for dissipation, and for the purpose of mounting onto the ECL3 LED EMERGENCY GEARTRAY.

The Electronic Control Circuitry of the Inverter ensures optimum Charging Levels, which allows a Full Charge of the relevant Battery Pack to be reached within 24 hours.

The Electronic Control Circuitry also prevents Deep Discharge and Overcharging of the Hermetically Sealed Lead-Acid Battery Packs, by monitoring Upper and Lower Voltage Levels of the Battery, and thereby ensuring a long Service Life.
 

The Lead Acid Battery Packs are securely held in place by means of Galvanized Steel brackets.

The automatic Changeover to and from Emergency Mode is carried out via an Electronic Circuit within the Inverter.

The ECL3 LED EMERGENCY GEARTRAY can operate in the Non-Maintained or Maintained Mode, depending on how the ECL3 LED EMERGENCY GEARTRAY Output Is Wired.

A charge indicating LED also features on the unit.

Connection to the Unswitched Mains 230 V AC Supply is via a 4 way, High Temperature Terminal Block which is well secured to the ECL3 LED EMERGENCY GEARTRAY, and exits on one side.

All terminal Blocks supplied with the ECL3 LED, are High Temperature Nylon 140°C, featuring wire protection clamp.

 

As an additional feature, the Self-Diagnostic System (See SDS) can be included (space permitting), which allows for Functional Testing of the Lamp, and Emergency Control Gear.
 

A full Duration Test is also programmed into the SDS Unit, allowing for a full discharge of the Battery Pack, after which, normal charging will resume. Any faults found are displayed via a second, multi-coloured LED.

Mounting of the ECL3 LED EMERGENCY GEARTRAY into the respective Luminaire, is effected by means of two M5 holes in the centre of the GEARTRAY.

 

A pre-formed and pre-punched, Highly Polished, 99% Pure Aluminium Reflector features on the Lamp Side of the Geartray. This Highly improves the Luminous efficiency of the LED Modules, and also serves to mount and secure the respective LED Modules.

 

The LUMINAIRE BODY is constructed by means of High Pressure Die Casting, from Grade LM6 Aluminium. The body, coated in chromate, is usually supplied as standard. However, the body can also be Epoxy Powder Coated in a variety of colours upon request.

The LUMINAIRE DIFFUSER is manufactured from High Impact Acrylic. This is held in place by means of 4, Zinc Plated Captive M6 Screws.

A Silicone Rubber Gasket forms an effective seal between the Diffuser and Luminaire Body, thus preventing the ingress of Water and Dust.

Cable entry into the Luminaire is provided by 20mm knockouts on 3 sides and the back of the body. Alternatively, a rosette also features in the back of the body.

MOUNTING of the Luminaire is by means of, 4 M6 blind tapped holes, or rosette, or via an optional mounting bracket.
 

 

                                                                

 

DIMENSIONS (mm) AND WEIGHTS (KG)

CODE

LENGTH

WIDTH

HEIGHT

WEIGHT

930000

410

270

198

4.65

930060

410

270

198

4.85

930120

410

270

198

5.00
930180

410

270

198

5.25
930240

410

270

198

5.60

934750

370

235

100

3.25

WEIGHTS REFER TO NICAD CONVERSION KITS. FOR LEAD ACID KITS, PLEASE ADD 250G TO EACH REQUIRED NICAD PACK.

 

ÉCLAT tm ECL3 LED EMERGENCY LUMINAIRES AND CONVERSION GEARTRAYS.

CODE

DESCRIPTION

LAMP WATTAGE

TIME DURATION

PERCENTAGE LIGHT OUTPUT

930000

ECL3 209 ECG M 20% 1HR LED DL 230V

19

1

20

930005

ECL3 409 ECG M 20% 1HR LED DL 230V

38

1

20

930010

ECL3 121 ECG M 20% 1HR LED DL 230V

21

1

20

930015

ECL3 221 ECG M 20% 1HR LED DL 230V

42

1

20

 

930060

ECL3 209 ECG M 20% 2HR LED DL 230V

19

2

20

930065

ECL3 409 ECG M 20% 2HR LED DL 230V

38

2

20

930070

ECL3 121 ECG M 20% 2HR LED DL 230V

21

2

20

930075

ECL3 221 ECG M 20% 2HR LED DL 230V

42

2

20

 

930120

ECL3 209 ECG M 50% 1HR LED DL 230V

19

1

50

930125

ECL3 409 ECG M 50% 1HR LED DL 230V

38

1

50

930130

ECL3 121 ECG M 50% 1HR LED DL 230V

21

1

50

930135

ECL3 221 ECG M 50% 1HR LED DL 230V

42

1

50

         

930180

ECL3 209 ECG M 100% 1HR LED DL 230V

19

1

100

930185

ECL3 409 ECG M 100% 1HR LED DL 230V

38

1

100

930190

ECL3 121 ECG M 100% 1HR LED DL 230V

21

1

100

930195

ECL3 221 ECG M 100% 1HR LED DL 230V

42

1

100

         

930240

ECL3 209 ECG M 20% 3HR LED DL 230V

19

3

20

930245

ECL3 409 ECG M 20% 3HR LED DL 230V

38

3

20

930250

ECL3 121 ECG M 20% 3HR LED DL 230V

21

3

20

930255

ECL3 221 ECG M 20% 3HR LED DL 230V

42

3

20

         
934750 ECL3 409 ECG M 20% 1HR LED DL 230V CONVERSION GEARTRAY

38

1 20
934755 ECL3 409 ECG M 20% 2HR LED DL 230V CONVERSION GEARTRAY

38

2 20
934760 ECL3 409 ECG M 50% 1HR LED DL 230V CONVERSION GEARTRAY

38

1 50
934765 ECL3 409 ECG M 100% 1HR LED DL 230V CONVERSION GEARTRAY

38

1 100

734770

ECL3 409 ECG M 20% 3HR LED DL 230V CONVERSION GEARTRAY

38

3 20
         
ADD TO BASE CODE THE FOLLOWING POSSIBLE OPTIONS: -

N = NICAD BATTERY.

P = LEAD ACID BATTERY.

S = SELF DIAGNOSTIC SYSTEM.

C = CONVERSION UTILIZING YOUR OWN BODY + COVER OR LUMINAIRE.

E.G. = 930000NS.

      • = ECL3 209 LED EMERGENCY LUMINAIRE, POLYCARBONATE DIFFUSER, 19 WATT LED LAMPS, 230V MAINS SUPPLY, ELECTRONIC CONTROL GEAR, EMERGENCY MAINTAINED LUMINAIRE, 20% LIGHT OUTPUT, 1 HOUR DURATION, NICAD BATTERY PACK AND SELF DIAGNOSTIC SYSTEM.

PRODUCT CODES DO EXIST FOR MOST OF THE OPTIONS MENTIONED. HOWEVER THERE ARE TOO MANY TO LIST IN THE CATALOGUE. IN ORDER TO AVOID CONFUSION, OF CODES AND DESCRIPTIONS, PLACE THE WORD ‘CODE’ IN PLACE OF ANY NOT LISTED IN THE PREVIOUS PAGES.

E.G. = ‘CODE’NS ECL3 428 LED ECG M 100% 1HR
 

PACKS FOR DIFFERENT LAMPS, LIGHT OUTPUTS AND DURATIONS, AVAILABLE UPON REQUEST.

 

 

Home ] Up ] [OVA EMERGENCY LIGHTING] [ALTENBURGER] [ECLAT INVERTERS]

Send mail to anthony@eclat.co.za or mwtones@mweb.co.za with questions or comments about this web site.
Copyright © 2005 ECLAT LIGHTING. Telephone: +27 11 868 3779 / +27 11 868 2578. Fax: +27 11 868 2578. Mobile: +27 82 562 9620.
Last modified: July, 2010.
COPYRIGHTS © AND VARIOUS PATENTS SUBSIST IN THE PRODUCTS AND IN THE CONTENT OF THIS WEBSITE. UNAUTHORIZED DUPLICATION OF THE PRODUCTS AND OF THE CONTENT BY ANY MEANS IS STRICTLY PROHIBITED. UNAUTHORIZED DUPLICATION OF ANY PROPRIETY METHODS UTILIZED AND AS DESCRIBED IN THESE PRODUCTS AND THEIR RELATED DOCUMENTS, FOR ANY OTHER THAN OUR OWN INTENDED PURPOSES, IS STRICTLY PROHIBITED. THE CONTENT OF THIS WEBSITE, IT'S PRODUCTS AND IT'S DOCUMENTS ARE STRICTLY PRIVATE AND CONFIDENTIAL, AND SHALL UNDER NO CIRCUMSTANCES BE DISCLOSED TO ANY UNAUTHORIZED THIRD PARTIES, WITHOUT PRIOR AUTHORIZATION FROM THE WRITER. PERMISSION FOR SUCH DISCLOSURE AND/OR DUPLICATION OF THESE PRODUCTS AND THESE DOCUMENTS SHALL BE APPLIED FOR, AND CONFIRMED IN WRITING. FAILURE TO FOLLOW THE ABOVE, WILL RESULT IN CIVIL AND CRIMINAL PROSECUTION.

ALL ITEMS MARKED IN RED, ARE NOT YET VERIFIED / ARE FUTURE PROJECTS / ARE IN PROGRESS.

ALL PAGES SUBJECT TO CHANGE AND TECHNICAL ERROR.