Home Up Feedback Contents Search

FLUORESCENT Inverters


FLUORESCENT Inverters HALOGEN Inverters INCANDESCENT Inverters HID Inverters LED Inverters Emergency Luminaires Portable Emergency Lighting

      [Under Construction]WE ARE PROUD TO PRESENT TO YOU, MORE THAN 280 QUALITY PRODUCTS. WE HOPE YOU ENJOY YOUR VISIT. ANY QUESTIONS PERTAINING TO THIS WEBSITE OR THE PRODUCTS SHOWN, CAN BE SENT TO anthony@eclat.co.za or mwtones@mweb.co.za PLEASE INCLUDE YOUR CONTACT DETAILS.

Home
Up
INVERTER 103 B
INVERTER 203 C
INVERTER 303 D
INVERTER 104 B NM
INVERTER 104 B M
INVERTER 204 C
INVERTER 304 D
INVERTER 105 D
INVERTER 205 D
INVERTER 305 D
INVERTER 105 DL
INVERTER 205 DL
INVERTER 105 D2X
INVERTER 105 DS
INVERTER 105 P
INVERTER 205 P
INVERTER 305 P
INVERTER 105 PL
INVERTER 205 PL
INVERTER 105 P2X
INVERTER 105 PS
INVERTER 106 D
INVERTER 106 DL
INVERTER 106 P
INVERTER 106 PL
INVERTER 108 D
INVERTER 108 DL
INVERTER 112 D
INVERTER 112 DL
INVERTER 112 P
INVERTER 112 PL
INVERTER 116 D
INVERTER 116 DL
INVERTER 116 P
INVERTER 116 PL
INVERTER 116 P ESU T
INVERTER 216 P ESU T
INVERTER 106 F
INVERTER 112 F
INVERTER 124 F
INVERTER 148 F
INVERTER 1110 F
INVERTER 1220 F
INVERTER 106 A
INVERTER 112 A
INVERTER 124 A
INVERTER 148 A
INVERTER 1110 A
INVERTER 1220 A
SELF DIAGNOSTIC (SDS)
SUB STATIONS (ESU)
VALID COMBINATIONS 1
VALID COMBINATIONS 2
CALCULATOR
WIRING DIAGRAMS
CENTRAL BATTERY (CBS)

Hit Counter

 

ÉCLAT INVERTERS PHOTO GALLERY.

INVERTER 104 B NM ON PRODUCTION LINES AND READY FOR TEST PROCESS

104 B NM INVERTERS BY THE DOZEN

104 B NM TESTED, READY FOR PACKING.

104 B M IN HOUSED FORMAT.

105 D INVERTER ON ASSEMBLY LINES.

105 D SOLDIERS READY FOR FIRST TEST.

105 D INVERTERS - TESTED, FULLY ASSEMBLED, READY TO WORK, WITH NICAD SIDE X SIDE PACK.

INVERTER 105 D WITH NICAD STICK PACK.

106 D INVERTER WITH NICAD STICK PACK

INVERTER 106 D SMALL AND POWERFUL.

108 INVERTER WITH NICAD PACKS.

112 D INVERTER WITH NICAD SIDE X SIDE PACKS.

112 P INVERTER WITH LEAD ACID PACKS.

INVERTER 116 D INVERTER READY FOR USE.

INVERTER 216 P INVERTER WITH LEAD ACID PACKS.

INVERTER 150 P NM WITH LEAD ACID PACK.

INVERTER 112 F, TESTED, HOUSED AND READY FOR BURN IN TEST.

SELF DIAGNOSTIC SYSTEM (SDS.) COMBINE WITH ANY INVERTER.


FLUORESCENT INVERTER DESCRIPTORS.

THE FIRST DIGIT IN THE DESCRIPTOR INDICATES THE NOMINAL DURATION IN HOURS.

THE FOLLOWING TWO DIGITS (NICAD [B, C, D,]) INDICATE THE MINIMUM QUANTITY OF NICAD CELLS.

THE FOLLOWING TWO DIGITS (LEAD ACID [P]) INDICATE THE MINIMUM VOLTAGE OF LEAD ACID CELLS.

THE EXTENSION OF LETTERS AND NUMBERS INDICATES ONE, OR COMBINATION OF THE FOLLOWING: -

 

2X          =        TWIN LAMP INVERTER. BOTH LAMPS MAINTAINED EMERGENCY LIGHTING.

A            =        FED DIRECT FROM EXTERNAL POWER SOURCE WITHOUT AUTOMATIC CHANGEOVER.

B            =        NICAD CELL, DETERMINED BY DURATION AND INVERTER CURRENT.

C            =        NICAD CELL, DETERMINED BY DURATION AND INVERTER CURRENT.

D            =        NICAD CELL, DETERMINED BY DURATION AND INVERTER CURRENT.

ESU        =        EMERGENCY SUB STATION UNIT. INVERTER FOR SUB STATION LIGHTING.

F            =        FED FROM EXTERNAL POWER SOURCE WITH AUTOMATIC CHANGEOVER.

i             =        INCANDESCENT LAMP INVERTER.

L            =        LIGHT SENSOR EQUIPPED INVERTER.

M           =        MAINTAINED EMERGENCY LIGHTING INVERTER. (ALL ARE, EXCEPT WHERE STATED.

                       'M' TYPE INVERTERS CAN ALSO BE UTILIZED AS 'NM' TYPES.)

NM         =        NON MAINTAINED EMERGENCY LIGHTING INVERTER.

P            =        LEAD ACID CELL.

S            =        INVERTER EQUIPPED WITH STANDBY FUNCTION AND REQUIRED CONNECTIONS.

T            =        INVERTER EQUIPPED WITH EXTERNAL TIMER FUNCTION AND REQUIRED CONNECTIONS.


FLUORESCENT INVERTER DESCRIPTORS.

IN THE DESCRIPTORS FOR THE 'A' AND 'F' TYPES: -

THE FIRST DIGIT IN THE DESCRIPTOR INDICATES THE NOMINAL DURATION IN HOURS.

THE FOLLOWING TWO OR THREE DIGITS INDICATE THE MINIMUM EXTERNAL D.C. SUPPLY VOLTAGE.

THE EXTENSION OF LETTERS AND NUMBERS INDICATES ONE, OR COMBINATION OF THE FOLLOWING: -

 

A            =        FED DIRECT FROM EXTERNAL POWER SOURCE WITHOUT AUTOMATIC CHANGEOVER.

F            =        FED FROM EXTERNAL POWER SOURCE WITH AUTOMATIC CHANGEOVER.

BOTH TYPES ARE NOT EQUIPPED WITH CHARGING CAPABILITIES. THIS IS ACHIEVED EXTERNALLY.


FLUORESCENT INVERTER DESCRIPTORS.

MOST OPTIONS LISTED, CAN BE SUCCESSFULLY COMBINED. IF YOU DO NOT SEE YOUR SPECIFIC REQUIREMENT LISTED, OR YOU REQUIRE SOMETHING NEW, PLEASE FEEL FREE TO CONTACT US.

SEE CONTACT DETAILS AT THE FOOT OF ANY PAGE.


 

Home ] Up ] INVERTER 103 B ] INVERTER 203 C ] INVERTER 303 D ] INVERTER 104 B NM ] INVERTER 104 B M ] INVERTER 204 C ] INVERTER 304 D ] INVERTER 105 D ] INVERTER 205 D ] INVERTER 305 D ] INVERTER 105 DL ] INVERTER 205 DL ] INVERTER 105 D2X ] INVERTER 105 DS ] INVERTER 105 P ] INVERTER 205 P ] INVERTER 305 P ] INVERTER 105 PL ] INVERTER 205 PL ] INVERTER 105 P2X ] INVERTER 105 PS ] INVERTER 106 D ] INVERTER 106 DL ] INVERTER 106 P ] INVERTER 106 PL ] INVERTER 108 D ] INVERTER 108 DL ] INVERTER 112 D ] INVERTER 112 DL ] INVERTER 112 P ] INVERTER 112 PL ] INVERTER 116 D ] INVERTER 116 DL ] INVERTER 116 P ] INVERTER 116 PL ] INVERTER 116 P ESU T ] INVERTER 216 P ESU T ] INVERTER 106 F ] INVERTER 112 F ] INVERTER 124 F ] INVERTER 148 F ] INVERTER 1110 F ] INVERTER 1220 F ] INVERTER 106 A ] INVERTER 112 A ] INVERTER 124 A ] INVERTER 148 A ] INVERTER 1110 A ] INVERTER 1220 A ] SELF DIAGNOSTIC (SDS) ] SUB STATIONS (ESU) ] VALID COMBINATIONS 1 ] VALID COMBINATIONS 2 ] CALCULATOR ] WIRING DIAGRAMS ] CENTRAL BATTERY (CBS) ] [OVA EMERGENCY LIGHTING] [ALTENBURGER] [ECLAT INVERTERS]

Send mail to anthony@eclat.co.za or mwtones@mweb.co.za with questions or comments about this web site.
Copyright © 2005 ECLAT LIGHTING. Telephone: +27 11 868 3779 / +27 11 868 2578. Fax: +27 11 868 2578. Mobile: +27 82 562 9620.
Last modified: July, 2010.
COPYRIGHTS © AND VARIOUS PATENTS SUBSIST IN THE PRODUCTS AND IN THE CONTENT OF THIS WEBSITE. UNAUTHORIZED DUPLICATION OF THE PRODUCTS AND OF THE CONTENT BY ANY MEANS IS STRICTLY PROHIBITED. UNAUTHORIZED DUPLICATION OF ANY PROPRIETY METHODS UTILIZED AND AS DESCRIBED IN THESE PRODUCTS AND THEIR RELATED DOCUMENTS, FOR ANY OTHER THAN OUR OWN INTENDED PURPOSES, IS STRICTLY PROHIBITED. THE CONTENT OF THIS WEBSITE, IT'S PRODUCTS AND IT'S DOCUMENTS ARE STRICTLY PRIVATE AND CONFIDENTIAL, AND SHALL UNDER NO CIRCUMSTANCES BE DISCLOSED TO ANY UNAUTHORIZED THIRD PARTIES, WITHOUT PRIOR AUTHORIZATION FROM THE WRITER. PERMISSION FOR SUCH DISCLOSURE AND/OR DUPLICATION OF THESE PRODUCTS AND THESE DOCUMENTS SHALL BE APPLIED FOR, AND CONFIRMED IN WRITING. FAILURE TO FOLLOW THE ABOVE, WILL RESULT IN CIVIL AND CRIMINAL PROSECUTION.

ALL ITEMS MARKED IN RED, ARE NOT YET VERIFIED / ARE FUTURE PROJECTS / ARE IN PROGRESS.

ALL PAGES SUBJECT TO CHANGE AND TECHNICAL ERROR.