ÉCLAT 5 EMERGENCY FLUORESCENT RECESSED LUMINAIRE

The Modular ECL5 Recessed Body is available in nominal lengths of 600mm (2'), 1200mm (4'), 1500mm (5'). Available in Single, Twin, Three, and Four Lamp Versions.

The ECL5 is a complete range of recessed fluorescent Luminaires manufactured specifically for exposed T ceilings.

The ECL5 Luminaires are designed for maximum efficiency, utilising 26mmØ T8 Energy Saving Lamps, with 16mmØ T5 Lamps and a shallow body being an option.

Careful attention has been paid to glare control in all versions of ECL5 Luminaires. AR 27 diffusers feature an array of rectangular prisms, which diffuses the lamp glare, and reduces surface brightness. The low brightness (LLB), and double parabolic (DLB) Louvres are designed and Manufactured to very fine tolerances.

Access for lamp replacement and Control Gear Maintenance is achieved by easing the diffuser or Louvre downward, disengaging the retaining springs on one side and allowing the frame to hinge downward from the springs on the other side. This prevents unnecessary handling of the diffuser.

In the Case of Linear Lamps, Rotor Lock Lampholders ensure secure Lamp Location, which can withstand vibration and also allows for simplified lamp replacement. 2G11 Lampholders are offered for the Compact Lamp Versions.

Spot Welded Corners within the Body ensure a fair amount of rigidity. The ECL5 Body is manufactured from 0.8mm mild steel, pre-treated and finished in a white powder coating.

Conventional Control Gear is made up either of SABS Approved Chokes, Capacitors, Wire and Starters. Approved ECG’s or Dimmable ECG’s are also offered as standard. In ALL cases, High Temperature Terminal Blocks are included as standard.

In addition, all Variations can be offered as Emergency Maintained Luminaires. Emergency Control Gear comprises a suitable quantity of High Temperature 70° C Ni-Cad Cells, a full range of High Quality, ÉCLAT Electronic Inverters, which incorporate a built in Battery Charging System and Charge Indicator LED, which is visible on the outer edge of the Louvre.

All ÉCLAT Inverters are housed in an extruded Aluminium Casing and are suitable for use with any Fluorescent Lamp from 4 Watt through to 80 Watt, including Compact Fluorescent Lamps.

In most cases, the Battery Packs are secured within the Body by means of Pre- Fabricated Plastic Battery Brackets.

As an additional feature, a Self-Diagnostic System can be included in the ECL5, which allows for periodic testing of the Lamp and Emergency Control Gear. A Full Duration Test is also programmed into the Unit, allowing for a full discharge of the Battery Pack, after which normal charging will resume. Any faults found are displayed via a multi-coloured LED.

THE ECL5, NEAT AND SIMPLE.

DIMENSIONS (mm) AND WEIGHTS (KG)

CODE

LENGTH

DEPTH

HEIGHT

WEIGHT

FOR DETAILED WEIGHTS AND DIMENSIONS, PLEASE SEE THE SPECIFICATION CHART LISTED BELOW. THERE ARE JUST TOO MANY TO LIST IN JUST THIS LITTLE SPACE!

         

LENGTH IS OVERALL LENGTH. FOR DETAILS, SEE OPTIONS BELOW.

ÉCLAT tm ECL5 RECESSED EMERGENCY LUMINAIRE SPECIFICATIONS (TYPICAL.)

CODE

DESCRIPTION

LAMP WATTS

DURATION (HRS)

LIGHT OUTPUT

LENGTH

HEIGHT

WIDTH

WEIGHT

24385 ECL5 218 CCG M 20% 1HR

2x18

1

20

600

90

300

4.35

24386 ECL5 236 CCG M 20% 1HR

2x36

1

20

1200

90

300

5.65

24387 ECL5 258 CCG M 20% 1HR

2x58

1

20

1500

90

300

7.85

24388 ECL5 318 CCG M 20% 1HR

3x18

1

20

600

90

600

5.31

24389 ECL5 336 CCG M 20% 1HR

3x36

1

20

1200

90

600

7.50

24390 ECL5 358 CCG M 20% 1HR

3x58

1

20

1500

90

500

12.80

24391 ECL5 418 CCG M 20% 1HR

4x18

1

20

600

90

600

5.60

24392 ECL5 436 CCG M 20% 1HR

4x36

1

20

1200

90

600

11.30

24395 ECL5 218 CCG M 20% 2HR

2x18

2

20

600

90

300

4.65

24400 ECL5 236 CCG M 20% 2HR

2x36

2

20

1200

90

300

5.95

24405 ECL5 258 CCG M 20% 2HR

2x58

2

20

1500

90

300

8.15

24410 ECL5 318 CCG M 20% 2HR

3x18

2

20

600

90

600

5.61

24415 ECL5 336 CCG M 20% 2HR

3x36

2

20

1200

90

600

7.80

24420 ECL5 358 CCG M 20% 2HR

3x58

2

20

1500

90

500

13.10

24425 ECL5 418 CCG M 20% 2HR

4x18

2

20

600

90

600

5.90

24430 ECL5 436 CCG M 20% 2HR

4x36

2

20

1200

90

600

11.60

24575 ECL5 218 CCG M 50% 1HR

2x18

1

50

600

90

300

5.05

24580 ECL5 236 CCG M 50% 1HR

2x36

1

50

1200

90

300

6.15

24585 ECL5 258 CCG M 50% 1HR

2x58

1

50

1500

90

300

8.35

24590 ECL5 318 CCG M 50% 1HR

3x18

1

50

600

90

600

5.81

24595 ECL5 336 CCG M 50% 1HR

3x36

1

50

1200

90

600

8.00

24600 ECL5 358 CCG M 50% 1HR

3x58

1

50

1500

90

500

13.30

24605 ECL5 418 CCG M 50% 1HR

4x18

1

50

600

90

600

6.10

24610 ECL5 436 CCG M 50% 1HR

4x36

1

50

1200

90

600

11.80

24750 ECL5 218 CCG M 100% 1HR

2x18

1

100

600

90

300

5.65

24751 ECL5 236 CCG M 100% 1HR

2x36

1

100

1200

90

300

6.65

24752 ECL5 258 CCG M 100% 1HR

2x58

1

100

1500

90

300

8.85

24753 ECL5 318 CCG M 100% 1HR

3x18

1

100

600

90

600

6.31

24754 ECL5 336 CCG M 100% 1HR

3x36

1

100

1200

90

600

8.50

24755 ECL5 358 CCG M 100% 1HR

3x58

1

100

1500

90

500

13.80

24756 ECL5 418 CCG M 100% 1HR

4x18

1

100

600

90

600

6.60

24757 ECL5 436 CCG M 100% 1HR

4x36

1

100

1200

90

600

12.30

24760 ECL5 218 CCG M 20% 1HR

2x18

3

20

600

90

300

5.05

24761 ECL5 236 CCG M 20% 1HR

2x36

3

20

1200

90

300

6.15

24762 ECL5 258 CCG M 20% 1HR

2x58

3

20

1500

90

300

8.35

24763 ECL5 318 CCG M 20% 1HR

3x18

3

20

600

90

600

5.81

24764 ECL5 336 CCG M 20% 1HR

3x36

3

20

1200

90

600

8.00

24765 ECL5 358 CCG M 20% 1HR

3x58

3

20

1500

90

500

13.30

24766 ECL5 418 CCG M 20% 1HR

4x18

3

20

600

90

600

6.10

24767 ECL5 436 CCG M 20% 1HR

4x36

3

20

1200

90

600

11.80

WEIGHTS REFER TO LUMINAIRES EQUIPPED WITH NICAD BATTERY PACKS. FOR LEAD ACID CELLS, PLEASE ADD 250G TO EACH REQUIRED NICAD PACK.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

    ADD TO BASE CODE THE FOLLOWING POSSIBLE OPTIONS: -

    N = NICAD BATTERY.

    P = LEAD ACID BATTERY.

    S = SELF DIAGNOSTIC SYSTEM.

    C = CONVERSION UTILIZING YOUR OWN BODY + COVER OR LUMINAIRE.

    E.G. = 24751NS.

    = ECL5 236 CCG M 50% 1HR, NICAD BATTERY AND SELF DIAGNOSTIC SYSTEM.

    IN PLACE OF CCG, (CONVENTIONAL CONTROL GEAR) THE FOLLOWING OPTIONS ARE ALSO AVAILABLE: -

    ECG ELECTRONIC CONTROL GEAR.
    DIM ECG    DIMMABLE ELECTRONIC CONTROL GEAR.

    TO SELECT THE ECG OR DIM ECG OPTION, REPLACE CCG WITH EITHER ECG OR DIM ECG.

    E.G. = ECL5 236 ECG M 50% 1HR.

    E.G. = ECL5 258 DIM ECG M 50% 1HR.

    A MAINTAINED LUMINAIRE WILL OPERATE AS A STANDARD MAINS LUMINAIRE, AND UNDER MAINS FAIL CONDITIONS, THE EMERGENCY LAMP WILL CONTINUE TO RUN FOR THE SPECIFIED DURATION AND LIGHT OUTPUT. TO SELECT A NON-MAINTAINED LUMINAIRE (LAMP OPERATES ONLY UNDER MAINS FAIL CONDITIONS):-

    TO SELECT THE NM OPTION, REPLACE THE M IN THE LUMINAIRE DESCRIPTION WITH NM.

    E.G. = ECL5 136 CCG NM 50% 1HR.

    NOTE: DUE TO THE LUMINAIRE BEING NON-MAINTAINED, IT MAKES MORE SENSE TO SELECT A SINGLE LAMP LUMINAIRE, AS THE SECOND LAMP WILL NEVER BECOME OPERATIONAL, UNLESS IT IS PROVIDED WITH A SECOND INVERTER AND BATTERY PACK. HOWEVER, ON THE 18-WATT OPTION, TWO  LAMPS CAN BE FED OFF A SINGLE INVERTER AND BATTERY PACK, HOWEVER THE TIME DURATION WOULD THEN BE HALVED.

    AS EXTENDED OPTIONS:-

    EXISTING ON SITE LUMINAIRES CAN BE FACTORY RETROFITTED, MAKING FOR AN EFFECTIVE EMERGENCY OR ELECTRONIC CONTROL GEAR LUMINAIRE AT REASONABLE COST.

    VARIOUS MAINS OPERATING VOLTAGES OTHER THAN THE STANDARD 230V AC ARE ALSO AVAILABLE: -

    12V, 24V, 32V, 48V, 110V, AND 240V AC.

    12V, 24V, 32V, 48V, 110V, AND 240V DC. APPEND TO THE END OF THE LUMINAIRE DESCRIPTION.

    E.G. = ECL5 136 CCG NM 50% 1HR 12V DC.

    WARRANTY PERIOD FOR EMERGENCY CONTROL GEAR:-

    ONE YEAR ON INVERTER, SIX MONTHS ONLY ON BATTERY PACKS, DUE TO NEGLECT AND ABUSE.

    VERY IMPORTANT NOTE: -

    PRODUCT CODES DO EXIST FOR MOST OF THE OPTIONS MENTIONED. HOWEVER THERE ARE TOO MANY TO LIST IN THE CATALOGUE. IN ORDER TO AVOID CONFUSION, OF CODES AND DESCRIPTIONS, PLACE THE WORD ‘CODE’ IN PLACE OF ANY NOT LISTED IN THE PREVIOUS PAGES.

    E.G. = ‘CODE’NS ECL5 236 ECG M 100% 1HR

    LUMINAIRES FOR DIFFERENT LAMPS, LIGHT OUTPUTS AND DURATIONS, AVAILABLE UPON REQUEST.

 

Home ] Up ] [OVA EMERGENCY LIGHTING] [ALTENBURGER] [ECLAT INVERTERS]

Send mail to anthony@eclat.co.za or mwtones@mweb.co.za with questions or comments about this web site.
Copyright © 2005 ECLAT LIGHTING. Telephone: +27 11 868 3779 / +27 11 868 2578. Fax: +27 11 868 2578. Mobile: +27 82 562 9620.
Last modified: July, 2010.
COPYRIGHTS © AND VARIOUS PATENTS SUBSIST IN THE PRODUCTS AND IN THE CONTENT OF THIS WEBSITE. UNAUTHORIZED DUPLICATION OF THE PRODUCTS AND OF THE CONTENT BY ANY MEANS IS STRICTLY PROHIBITED. UNAUTHORIZED DUPLICATION OF ANY PROPRIETY METHODS UTILIZED AND AS DESCRIBED IN THESE PRODUCTS AND THEIR RELATED DOCUMENTS, FOR ANY OTHER THAN OUR OWN INTENDED PURPOSES, IS STRICTLY PROHIBITED. THE CONTENT OF THIS WEBSITE, IT'S PRODUCTS AND IT'S DOCUMENTS ARE STRICTLY PRIVATE AND CONFIDENTIAL, AND SHALL UNDER NO CIRCUMSTANCES BE DISCLOSED TO ANY UNAUTHORIZED THIRD PARTIES, WITHOUT PRIOR AUTHORIZATION FROM THE WRITER. PERMISSION FOR SUCH DISCLOSURE AND/OR DUPLICATION OF THESE PRODUCTS AND THESE DOCUMENTS SHALL BE APPLIED FOR, AND CONFIRMED IN WRITING. FAILURE TO FOLLOW THE ABOVE, WILL RESULT IN CIVIL AND CRIMINAL PROSECUTION.

ALL ITEMS MARKED IN RED, ARE NOT YET VERIFIED / ARE FUTURE PROJECTS / ARE IN PROGRESS.

ALL PAGES SUBJECT TO CHANGE AND TECHNICAL ERROR.