ÉCLAT 80 DIE CAST ALUMINIUM EMERGENCY FLOODLIGHT

ECL80 EMERGENCY FLOODLIGHT, TOUGH, COMPACT DIE CAST ALUMINIUM FLOODLIGHT.

A High Performance Floodlight with a well proven track record. Its high intensity, Wide Beam Spread, fulfils the essential requirements for efficient General Area and Medium Mast Lighting.

When the ECL80 is supplied with a Hammered Anodised Aluminium Reflector it gives a Lower Intensity, But Wider Light Distribution For Lower Mounting Heights. Further modifications can be done making it suitable for special applications.

In the ECL80, Both the Luminaire Body and Control Gear Housing are of Die-Cast Aluminium. This allows for Minimal Heat Transfer and thereby, prolonging the Service Life of Heat Sensitive Components.

The ECL80 Lamp and Control Gear are Housed Separately from each other, But Remain Integral parts of the overall assembly of the Luminaire.

An additional feature of the design is a system which allows for Easy Replacement Of The SABS Approved Control Gear; this is a Separate And Easily Removable Geartray.

Lamp Replacement is accomplished via a side mounted Gasketed Cast Aluminium Lampholder Housing, which is held in place by Two Machine Screws And Keyhole Slots.

The Aluminium Lampholder Housing also holds captive, the Porcelain E40 Lampholder. This method of lamp replacement prevents disturbance of the 5mm Armour-Plated And Gasketed Glass.

Lamp Options include High Pressure Sodium and Metal Halide Lamps, in the ranges of 150W, 250W, and 400W.

Connection Between The Lampholder And Control Gear Housings is via a Suitably Glanded 3 Core Silicone Cabtyre.

ECLAT AUTOLITE UNITS (See AUTOLITE) can be incorporated into the Luminaire, which features a 250W Or 500W Single ended Auxiliary Tungsten Halogen Lamp. This allows for the Bridging Of The Restrike And Warm-Up 20 Minute Period, following a power dip or momentary power failure.

All Fasteners featured on the ECL80 are of Marine Grade Stainless Steel, thereby preventing them from being attacked by corrosive environments.

Mounting Of The ECL80 Floodlight is accomplished via a sturdy, Mild Steel Hot-Dipped Galvanised Bracket, making it Ideally Suitable For Mast Mounting.

The Maintained Emergency Lighting Options have the required Emergency Control Gear housed in a separate Enclosure from Lamp and Standard Control Gear. However, this Emergency Control Gear once again becomes an integral part of the Luminaire.

The ECL80 EMERGENCY FLOODLIGHT Luminaire, features the powerful range of ECLAT HID Inverters (See ECLAT HID INVERTERS) which are suitable for all HID Lamps, with Light Outputs set at a nominal 100% Light Output.

Time Durations from 0.5 Hour to 3 Hour can be accommodated on the ECL80 EMERGENCY GEARTRAY dependent upon the Lamp Type and Wattage in use.

A suitable set of High Temperature Lead Acid Batteries are offered as Standard Equipment.

The Charger (which forms part of the Inverter Circuitry) and Inverter’s Electronic Components are mounted within a 1-mm thick Extruded Aluminium housing, which also serves as a Heatsink for dissipation, and for the purpose of mounting into the ECL80 EMERGENCY CONTROL GEAR HOUSING.

The Electronic Control Circuitry of the Inverter ensures optimum Charging Levels, which allows a Full Charge of the relevant Battery Pack to be reached within 24 hours.

The Electronic Control Circuitry also prevents Deep Discharge and Overcharging of the Hermetically Sealed Lead-Acid, by monitoring Upper and Lower Voltage Levels of the Battery, and thereby ensuring a long Service Life.
 

The Lead Acid Battery Packs are securely held in place by means of Galvanized Steel brackets.

The automatic Changeover to and from Emergency Mode is carried out via an Electronic Circuit within the Inverter.

The ECL80 EMERGENCY FLOODLIGHT can be made to operate in the Non-Maintained or Maintained Mode, depending on whether the Luminaire is equipped with Standard Control Gear, and also upon how the ECL80 Mains Connections and Output Connections are wired.

A Charge Indicating LED also features on EMERGENCY CONTROL GEAR HOUSING and is visible from the outside of the Unit.

Connection to the Unswitched Mains 230 V AC Supply is via a 4 way, High Temperature Terminal Block which is well secured to the ECL80 EMERGENCY GEARTRAY, and exits on one side of the EMERGENCY CONTROL GEAR HOUSING.

All Terminal Blocks supplied with the ECL80, are High Temperature Nylon 140°C, featuring wire protection clamp.

 

As an additional feature, the Self-Diagnostic System (See SDS) can be included (space permitting), which allows for Functional Testing of the Lamp, Battery Packs, and Emergency Control Gear.
 

A full Duration Test is also programmed into the SDS Unit, allowing for a full discharge of the Battery Pack, after which, normal charging will resume. Any faults found are displayed via a second, multi-coloured LED, which is also visible from the outside of the Unit.

 

DIMENSIONS (mm) AND WEIGHTS (KG)

CODE

LENGTH

WIDTH

DEPTH

WEIGHT

500405

460

345

215

12.8

500410

460

345

215

13.8

500415

460

345

215

15.3

500420

460

345

215

16.8

500425

460

345

215

17.8

500430

460

345

215

20.7

500435

460

345

215

22.6

LENGTH IS BODY LENGTH INCLUDING CONTROL GEAR BOX. FOR FIXING BRACKET, ADD 250mm ONTO LENGTH. WIDTH INCLUDES LAMPHOLDER HOUSING.

ÉCLAT tm ECL80 SURFACE MOUNT EMERGENCY HID. FLOODLIGHT LUMINAIRES.

CODE

DESCRIPTION

LAMP WATTAGE

TIME DURATION

PERCENTAGE LIGHT OUTPUT

500405

ECL80 35 MH 230V CCG M 100% 1HR

35

1

100

500410

ECL80 50 MH 230V CCG M 100% 1HR

50

1

100

500415

ECL80 70 MH 230V CCG M 100% 1HR

70

1

100

500420

ECL80 100 MH 230V CCG M 100% 1HR

100

1

100

500425

ECL80 150 MH 230V CCG M 100% 1HR

150

1

100

500430

ECL80 250 MH 230V CCG M 100% 1HR

250

1

100

500435

ECL80 400 MH 230V CCG M 100% 1HR

400

1

100

         

500440

ECL80 70 HPS 230V CCG M 100% 1HR

70

1

100

500445

ECL80 100 HPS 230V CCG M 100% 1HR

100

1

100

500450

ECL80 150 HPS 230V CCG M 100% 1HR

150

1

100

500455

ECL80 250 HPS 230V CCG M 100% 1HR

250

1

100

500460

ECL80 400 HPS 230V CCG M 100% 1HR

400

1

100

         

500465

ECL80 50 MV 230V CCG M 100% 1HR

50

1

100

500470

ECL80 80 MV 230V CCG M 100% 1HR

80

1

100

500475

ECL80 125 MV 230V CCG M 100% 1HR

125

1

100

500480

ECL80 250 MV 230V CCG M 100% 1HR

250

1

100

500485

ECL80 400 MV 230V CCG M 100% 1HR

400

1

100

         

505405

ECL80 35 MH 230V CCG M 100% 1HR CONVERSION PACK

35

1

100

505410

ECL80 50 MH 230V CCG M 100% 1HR CONVERSION PACK

50

1

100

505415

ECL80 70 MH 230V CCG M 100% 1HR CONVERSION PACK

70

1

100

505420

ECL80 100 MH 230V CCG M 100% 1HR CONVERSION PACK

100

1

100

505425

ECL80 150 MH 230V CCG M 100% 1HR CONVERSION PACK

150

1

100

505430

ECL80 250 MH 230V CCG M 100% 1HR CONVERSION PACK

250

1

100

505435

ECL80 400 MH 230V CCG M 100% 1HR CONVERSION PACK

400

1

100

         

505440

ECL80 70 HPS 230V CCG M 100% 1HR CONVERSION PACK

70

1

100

505445

ECL80 100 HPS 230V CCG M 100% 1HR CONVERSION PACK

100

1

100

505450

ECL80 150 HPS 230V CCG M 100% 1HR CONVERSION PACK

150

1

100

505455

ECL80 250 HPS 230V CCG M 100% 1HR CONVERSION PACK

250

1

100

505460

ECL80 400 HPS 230V CCG M 100% 1HR CONVERSION PACK

400

1

100

         

505465

ECL80 50 MV 230V CCG M 100% 1HR CONVERSION PACK

50

1

100

505470

ECL80 80 MV 230V CCG M 100% 1HR CONVERSION PACK

80

1

100

505475

ECL80 125 MV 230V CCG M 100% 1HR CONVERSION PACK

125

1

100

505480

ECL80 250 MV 230V CCG M 100% 1HR CONVERSION PACK

250

1

100

505485

ECL80 400 MV 230V CCG M 100% 1HR CONVERSION PACK

400

1

100

         
ADD TO BASE CODE THE FOLLOWING POSSIBLE OPTIONS: -

NBR = NARROW BEAM REFLECTOR.

HR = HAMMERED REFLECTOR.

AL = AUTOLITE AUXILIARY LAMP.

S = SELF DIAGNOSTIC SYSTEM.

C = CONVERSION UTILIZING YOUR OWN BODY + COVER OR LUMINAIRE.

E.G. = 500470 HR AL S.

      • = ECL80 EMERGENCY FLOODLIGHT LUMINAIRE, 1x80 WATT HIGH INTENSITY DISCHARGE (HID.) LAMP, 230V MAINS SUPPLY, CONVENTIONAL CONTROL GEAR, EMERGENCY MAINTAINED LUMINAIRE, 100% LIGHT OUTPUT, 1 HOUR DURATION, HAMMERED REFLECTOR, AUTOLITE LAMP AND SELF DIAGNOSTIC SYSTEM.

PRODUCT CODES DO EXIST FOR MOST OF THE OPTIONS MENTIONED. HOWEVER THERE ARE TOO MANY TO LIST IN THE CATALOGUE. IN ORDER TO AVOID CONFUSION, OF CODES AND DESCRIPTIONS, PLACE THE WORD ‘CODE’ IN PLACE OF ANY NOT LISTED IN THE PREVIOUS PAGES.

E.G. = ‘CODE’ HR AL S ECL80 150 ECG M 100% 1HR
 

PACKS FOR DIFFERENT LAMPS, LIGHT OUTPUTS AND DURATIONS, AVAILABLE UPON REQUEST.

 

Home ] Up ] [OVA EMERGENCY LIGHTING] [ALTENBURGER] [ECLAT INVERTERS]

Send mail to anthony@eclat.co.za or mwtones@mweb.co.za with questions or comments about this web site.
Copyright © 2005 ECLAT LIGHTING. Telephone: +27 11 868 3779 / +27 11 868 2578. Fax: +27 11 868 2578. Mobile: +27 82 562 9620.
Last modified: July, 2010.
COPYRIGHTS © AND VARIOUS PATENTS SUBSIST IN THE PRODUCTS AND IN THE CONTENT OF THIS WEBSITE. UNAUTHORIZED DUPLICATION OF THE PRODUCTS AND OF THE CONTENT BY ANY MEANS IS STRICTLY PROHIBITED. UNAUTHORIZED DUPLICATION OF ANY PROPRIETY METHODS UTILIZED AND AS DESCRIBED IN THESE PRODUCTS AND THEIR RELATED DOCUMENTS, FOR ANY OTHER THAN OUR OWN INTENDED PURPOSES, IS STRICTLY PROHIBITED. THE CONTENT OF THIS WEBSITE, IT'S PRODUCTS AND IT'S DOCUMENTS ARE STRICTLY PRIVATE AND CONFIDENTIAL, AND SHALL UNDER NO CIRCUMSTANCES BE DISCLOSED TO ANY UNAUTHORIZED THIRD PARTIES, WITHOUT PRIOR AUTHORIZATION FROM THE WRITER. PERMISSION FOR SUCH DISCLOSURE AND/OR DUPLICATION OF THESE PRODUCTS AND THESE DOCUMENTS SHALL BE APPLIED FOR, AND CONFIRMED IN WRITING. FAILURE TO FOLLOW THE ABOVE, WILL RESULT IN CIVIL AND CRIMINAL PROSECUTION.

ALL ITEMS MARKED IN RED, ARE NOT YET VERIFIED / ARE FUTURE PROJECTS / ARE IN PROGRESS.

ALL PAGES SUBJECT TO CHANGE AND TECHNICAL ERROR.