SUBLUX & SECURLUX

 

  
PORTABLE EMERGENCY LIGHTING

Professional, Portable and Safe Searchlights, combined with outstanding high-performance.
 

 

SUBLUX:
Sealed professional searchlight ideal for diving sport amateurs.
SUBLUX is suitable for illumination at great depths (100 m) and thanks to the long Autonomy of its Batteries it is suitable for long dives without recharging the Batteries (continuous light for 4 hours).
A 10W halogen Lamp gives an extended beam (300 m approx. on surface).
It is fitted with sealed rechargeable batteries which, even after years of storage in discharged conditions, present no inconvenience at the moment of recharging.
Completely Maintenance-free.
SUBLUX comes complete with double handle and two Battery Chargers; one for charging from 230V AC Mains and one for charging from 12V Motor Vehicle Battery. The Lamp is enclosed in a strong case made of highly-resistant, shockproof and corrosion-proof plastic.

 

 

SECURLUX:
Professional Portable Lamp of improved and Intrinsic Safety II 2 G EEx e ib IIC T3, suitable for use in hazardous areas, according to the European Regulations 94/9/CE of 23/3/1994 (for Lamps) and 1999/92/CE of 16/12/1999 (for Installations.)
The Standards for the High Explosion area classification are given in EN 60079-10.

The Technical Specifications of Electric Installations in the classified areas are given in EN 60079-14.
Built In accordance with ATEX 94/9 CE.

CESI 03 ATEX 116 Certificate.
The Lamp can also be used in IIA and IIB Areas.
The T3 temperature class allows the lamp to be suitable with all materials with higher temperature classes (T2, T1.)
The lamp can be recharged in a safety area directly from 230V AC or 12V DC using the two chargers provided.
It is supplied in a strong case of resistant synthetic material.

 


SECURLUX SAFETY DATA:


II 2 G:-

Apparatus for Surface Installations of Category 2 with presence of Gas or Vapours, suitable for Zone 1 and generally suitable also for Zone 2.


EEx e ib:-

Increased Safety Apparatus with Intrinsic Safety Circuits of Category ib.


II C:-

Apparatus of Group IIC suitable for substances (gases) of Group IIC.


T3:-

Lamp Temperature Class (Maximum Surface Temperature.)


:-

Marking indicating conformity to applicable European Directives.


:-

Marking indicating conformity to Directive 94/9/EC and related Technical Standards.


CESI:-

Name of Laboratory that issued the Examination Certificate.


03 ATEX 116:-

Year 03 of Issue of Certificate; 116 Certificate Number.


0722:-

Number of Notified Body responsible for inspecting the Production System.

 

 

SUBLUX Technical Specifications:

  • IP67 protection rating.
  • Double insulated.
  • Case of polycarbonate.
  • Recharge 220/230V - 50/60hz.
  • Recharging time 24 hours.
  • Maximum Depth of Operation 100M.
  • Case Dimensions: 250 x 370 x 135mm.
  • Recharge from 12V DC Battery; Max. Absorption 6W.

 

SECURLUX Technical Specifications:

  • IP66 protection rating.
  • Double insulated.
  • Increased Safety Apparatus with Intrinsic Safety  II 2 G EEX e ib IIC T3.
  • Case of Thermoplastic Material.
  • Recharge 220/230V - 50/60hz.
  • Recharging time 24 hours.
  • Working Temperature -20șC +40șC.
  • Case Dimensions: 250 x 370 x 130mm.
  • Recharge from 12V DC Battery; Max. Absorption 6W.

Accessories:

Chargers: Included.
 

 

 

Home ] Up ] [OVA EMERGENCY LIGHTING] [ALTENBURGER] [ECLAT INVERTERS]

Send mail to anthony@eclat.co.za or mwtones@mweb.co.za with questions or comments about this web site.
Copyright © 2005 ECLAT LIGHTING. Telephone: +27 11 868 3779 / +27 11 868 2578. Fax: +27 11 868 2578. Mobile: +27 82 562 9620.
Last modified: July, 2010.
COPYRIGHTS © AND VARIOUS PATENTS SUBSIST IN THE PRODUCTS AND IN THE CONTENT OF THIS WEBSITE. UNAUTHORIZED DUPLICATION OF THE PRODUCTS AND OF THE CONTENT BY ANY MEANS IS STRICTLY PROHIBITED. UNAUTHORIZED DUPLICATION OF ANY PROPRIETY METHODS UTILIZED AND AS DESCRIBED IN THESE PRODUCTS AND THEIR RELATED DOCUMENTS, FOR ANY OTHER THAN OUR OWN INTENDED PURPOSES, IS STRICTLY PROHIBITED. THE CONTENT OF THIS WEBSITE, IT'S PRODUCTS AND IT'S DOCUMENTS ARE STRICTLY PRIVATE AND CONFIDENTIAL, AND SHALL UNDER NO CIRCUMSTANCES BE DISCLOSED TO ANY UNAUTHORIZED THIRD PARTIES, WITHOUT PRIOR AUTHORIZATION FROM THE WRITER. PERMISSION FOR SUCH DISCLOSURE AND/OR DUPLICATION OF THESE PRODUCTS AND THESE DOCUMENTS SHALL BE APPLIED FOR, AND CONFIRMED IN WRITING. FAILURE TO FOLLOW THE ABOVE, WILL RESULT IN CIVIL AND CRIMINAL PROSECUTION.

ALL ITEMS MARKED IN RED, ARE NOT YET VERIFIED / ARE FUTURE PROJECTS / ARE IN PROGRESS.

ALL PAGES SUBJECT TO CHANGE AND TECHNICAL ERROR.