GENERATOR ACCESSORIES.

 

GENERATOR AUTOMATIC START AND CONTROL DEVICES: -

 

These allow the Power Generator to Start Automatically, so as to supply power within a few seconds of the interruption of the Mains Power Supply.


They check that the System is working correctly, and also switch off and disconnect the loads after an appropriate cooling down time, once the mains power supply is restored.

 

These then reset the System so that it is ready for operation if the mains power fails again. All generators with Diesel Engines can be equipped with an Automatic Start Panel, which must be chosen in accordance with the Generator Power Rating.

 


AUTOMATIC START AND CONTROL PANEL M96: -

 

CONTROL PANEL M96, is the Simplest and Most Economical Model: -

  • M96 is suitable for Power Ratings of up to 40 KVA.

  • It has a set of four-pole, power switching contactors with Mechanical and Electrical interlocks.

  • Its Automatic Start Program includes 3 Starting Cycles on mains failure.

  • Automatic and Manual Control Pushbuttons.

  • The Control Panel has an Audible and Visual Alarm for Low Oil Pressure / High Water Temperature.

  • An automatic Battery Charger keeps the Battery in fully charged condition.

  • The Control Panel is made according to CEI 17-13 Standards.

  • Order Code 50782 from 5 to 25 KVA.

  • Order Code 50783 from 30 to 40 KVA for model 15 MDE.
     

             

 

AUTOMATIC START AND CONTROL PANEL M96 TECHNICAL SPECIFICATIONS: -

  • INSTRUMENTS: -

    • Digital Voltmeter.

    • Digital Frequency Meter.

    • Digital Hour Counter.

     

  • AUTOMATIC CONTROL: -

    • Electronic Unit Complete with Pushbuttons for: -

    • Operation in MANUAL or AUTOMATIC Modes.

    • 3 Starting Cycles.

    • Start and Stop Pushbuttons.
       

  • STATUS INDICATORS: -

    • Mains Presence.

    • Mains contactor closed.

    • Generator unit contactor closed.

    • Start unsuccessful.

    • Battery charger in operation.

     

  • PROTECTIONS: -

    • Simultaneous visual and audible alarms indicating A stop, caused by: -

    • Low oil pressure.

    • High engine temperature.
       

  • SERVICES: -

    • Automatic battery charger.

     

  • POWER: -

    • 4-pole contactors for mains and generator unit.

    • Mechanical and electrical interlock.

 


AUTOMATIC START AND CONTROL PANEL FOR LEM GENERATOR MODELS: -

 

TO BE ORDERED WITH THE GENERATOR UNIT.

 

LEM CONTROL PANEL is the Most Complete and Advanced Model: -

  •  LEM is suitable for Power Ratings of up to 210 KVA.

  • The panel is made to CEI 17-13 standards.

  • It has a set of four-pole, power switching contactors with Mechanical and Electrical interlocks.

  • Its Automatic Start Program includes Starting Cycles on mains failure.

  • Automatic, Manual, Test, Control Pushbuttons.

  • The Control Panel has an Audible and Visual Alarm for Low Oil Pressure / High Water Temperature.

  • An automatic Battery Charger keeps the Battery in fully charged condition.

  • The Control Panel is made according to CEI 17-13 Standards.

 

    

 

AUTOMATIC START AND CONTROL PANEL LEM TECHNICAL SPECIFICATIONS: -

  • INSTRUMENTS: -

    • Voltmeter.

    • Ammeter.

    • Frequency Meter.

    • Hour Counter.

     

  • AUTOMATIC CONTROL: -

    • Electronic Unit Complete with Pushbuttons for: -

    • Operation in MANUAL, AUTOMATIC, STOP or TEST Modes.

    • Starting Cycles on Mains Failure.

    • Start and Stop Pushbuttons.
       

  • STATUS INDICATORS: -

    • Mains Presence.

    • Mains contactor closed.

    • Generator Unit Presence.

    • Generator unit contactor closed.

    • Start unsuccessful.

    • Battery charger in operation.

    • Low Oil Pressure.

    • High Engine Temperature.

     

  • PROTECTIONS: -

    • Simultaneous visual and audible alarms indicating A stop, caused by: -

    • Low oil pressure.

    • High engine temperature.
       

  • SERVICES: -

    • Automatic battery charger.

     

  • POWER: -

    • 4-pole contactors for mains and generator unit.

    • Mechanical and electrical interlock.

     

LEM AUTOMATIC START AND CONTROL PANELS COMPATIBILITY CHART: -

 

 

 


SOUNDPROOFING KIT FOR LEM GENERATOR MODELS: -

 

These Soundproofing Kits are specially designed to further lower the noise of LEM Water Cooled Generators to a level of not more than 65-70 dB. (Measured at 7 metres.)


They are environmentally friendly, and lower noise pollution in places where noise is constituted to be a health hazard, for example, Hospitals, Construction Sites, Outdoor Shows and Public Events.
 

 

SOUNDPROOFING KIT TECHNICAL SPECIFICATIONS: -

  • Enclosure of welded steel Construction.

  • 2 mm sheeting thickness.

  • Can be installed indoors or outdoors.

  • Class 1 soundproofing material, with hard-wearing elements of suitable thickness and density.

  • Semi residential type exhaust pipe, with noise levels between 28 and 30 dBA.

  • Air intake silencers with soundproofing screens.

  • Flush handles with key lock.

  • Special sealing strips are applied to the doors, to ensure an efficient acoustic and weatherproof seal.

  • Strap hinges of galvanized steel.

  • Control panel window made of safety glass.

  • Louvred vent openings for protection from rain.

 

    

 

 

LEM SOUNDPROOFING KIT COMPATIBILITY CHART: -

 

 

Home ] Up ] [OVA EMERGENCY LIGHTING] [ALTENBURGER] [ECLAT INVERTERS]

Send mail to anthony@eclat.co.za or mwtones@mweb.co.za with questions or comments about this web site.
Copyright 2005 ECLAT LIGHTING. Telephone: +27 11 868 3779 / +27 11 868 2578. Fax: +27 11 868 2578. Mobile: +27 82 562 9620.
Last modified: July, 2010.
COPYRIGHTS AND VARIOUS PATENTS SUBSIST IN THE PRODUCTS AND IN THE CONTENT OF THIS WEBSITE. UNAUTHORIZED DUPLICATION OF THE PRODUCTS AND OF THE CONTENT BY ANY MEANS IS STRICTLY PROHIBITED. UNAUTHORIZED DUPLICATION OF ANY PROPRIETY METHODS UTILIZED AND AS DESCRIBED IN THESE PRODUCTS AND THEIR RELATED DOCUMENTS, FOR ANY OTHER THAN OUR OWN INTENDED PURPOSES, IS STRICTLY PROHIBITED. THE CONTENT OF THIS WEBSITE, IT'S PRODUCTS AND IT'S DOCUMENTS ARE STRICTLY PRIVATE AND CONFIDENTIAL, AND SHALL UNDER NO CIRCUMSTANCES BE DISCLOSED TO ANY UNAUTHORIZED THIRD PARTIES, WITHOUT PRIOR AUTHORIZATION FROM THE WRITER. PERMISSION FOR SUCH DISCLOSURE AND/OR DUPLICATION OF THESE PRODUCTS AND THESE DOCUMENTS SHALL BE APPLIED FOR, AND CONFIRMED IN WRITING. FAILURE TO FOLLOW THE ABOVE, WILL RESULT IN CIVIL AND CRIMINAL PROSECUTION.

ALL ITEMS MARKED IN RED, ARE NOT YET VERIFIED / ARE FUTURE PROJECTS / ARE IN PROGRESS.

ALL PAGES SUBJECT TO CHANGE AND TECHNICAL ERROR.