Home Up Feedback Contents Search

INVERTER 106 F


INVERTER 103 B INVERTER 203 C INVERTER 303 D INVERTER 104 B NM INVERTER 104 B M INVERTER 204 C INVERTER 304 D INVERTER 105 D INVERTER 205 D INVERTER 305 D INVERTER 105 DL INVERTER 205 DL INVERTER 105 D2X INVERTER 105 DS INVERTER 105 P INVERTER 205 P INVERTER 305 P INVERTER 105 PL INVERTER 205 PL INVERTER 105 P2X INVERTER 105 PS INVERTER 106 D INVERTER 106 DL INVERTER 106 P INVERTER 106 PL INVERTER 108 D INVERTER 108 DL INVERTER 112 D INVERTER 112 DL INVERTER 112 P INVERTER 112 PL INVERTER 116 D INVERTER 116 DL INVERTER 116 P INVERTER 116 PL INVERTER 116 P ESU T INVERTER 216 P ESU T INVERTER 106 F INVERTER 112 F INVERTER 124 F INVERTER 148 F INVERTER 1110 F INVERTER 1220 F INVERTER 106 A INVERTER 112 A INVERTER 124 A INVERTER 148 A INVERTER 1110 A INVERTER 1220 A SELF DIAGNOSTIC (SDS) SUB STATIONS (ESU) VALID COMBINATIONS 1 VALID COMBINATIONS 2 CALCULATOR WIRING DIAGRAMS CENTRAL BATTERY (CBS)

      [Under Construction]WE ARE PROUD TO PRESENT TO YOU, MORE THAN 280 QUALITY PRODUCTS. WE HOPE YOU ENJOY YOUR VISIT. ANY QUESTIONS PERTAINING TO THIS WEBSITE OR THE PRODUCTS SHOWN, CAN BE SENT TO anthony@eclat.co.za or mwtones@mweb.co.za PLEASE INCLUDE YOUR CONTACT DETAILS.

Home
Up

Hit Counter

 

ÉCLAT INVERTER 106F

 

The éCLAT 106F (1 = 1 Hour 06 = 6 Volt F = Fed From External Battery or DC Power Source) Inverter is a Small but robust Inverter which operates in the Maintained Mode.  The current consumption is in the order of 2A DC and is suitable for operation off 6 Volt DC External Power Supply, offering a Nominal Duration of 1 Hour, or for as Long as the External DC Power Source is Available, and is suitable for operating 9W - 58W Fluorescent Lamps. Light Output is dependent on the Lamp in use. A 9W Lamp will run at 100% Light Output. (See VALID COMBINATIONS)

 

The 'F' Series of Inverters do not have any Battery Charging Capabilities. This Charging is usually Provided for By the External Power Source. The Mains 230V AC Supply, is therefore required solely for the detection of a Mains Power Failure, and to allow for the change-over between the 230V AC Mains Supply and the External DC Power Source.

 

ÉCLAT INVERTER STANDARD FEATURES: -
 

Constant Light Output over entire Emergency Duration, except for the last few minutes - approximately 5 minutes. (Light Output Test Reports are available.)
Mains Presence / Charge Indicator LED (Optional.)
Supplied Complete with Colour Coded Wires for faster installation.
Robust, Mill Finish Extruded Aluminium Housing.
Low Profile: 31mm x 40mm x 208mm. H x W x L. (106F.)
Surface Mount Technology (SMT) Electronic Components.
Glass Fibre Printed Circuit Board (PCB.)
Solder Mask is a Feature on all Inverters, which assists in preventing Short Circuits and resultant Inverter failure in damp, corrosive or wet environments.
Battery Low Voltage Cut-off Protection.
Battery Over Voltage Cut-off Protection.
Mains Voltage Surge Protection.
Nominal Mains Input Voltage 230V A.C. 50 Hz ± 10%.
Failure Rate of less than 0.65%.
Design Life of 10 Years.
Inspection and Test Procedures are carried out TWICE on EACH and EVERY Inverter to ensure it’s Functionality. Full Test and Inspection procedure is available.
Light Output Tests (under a controlled environment) are carried out on a regular basis, to ensure that all Inverters conform to the set requirements.
One Type of Inverter is all that is required, to cater for all Types of Standard Control Gear, be this: -
Switched Start, Semi-Resonant, Rapid Start, Electronic, Dimmable Electronic (from any Manufacturer.) Please inquire for suitable Wiring Diagrams.

ÉCLAT INVERTER ADDITIONAL FEATURES: -
 

Inverters can be Resin Cast for Rugged Environments.
Data / Specification Sheets are available for each Inverter (except for the new products) should You require.
Can be combined with the ECLAT Self Diagnostic System (SDS) to allow for periodic Functional and Duration Tests. (See SDS.)

 

ADVANTAGES OF ÉCLAT INVERTERS: -
 

Light output remains constant over the entire Duration Period, irrespective of the lamp wattage, and irrespective of the Standard Control Gear used. (Will not run into a standard 2-pin lamp, the use of which, is contrary to International Regulations.)
Not limited to a specific Ampere Hour rating of External Power Source for a given Inverter.
Simple wiring of Inverters.
In it’s Standard form, the Inverter will accommodate any type of Ballast, be they - Electronic, Dimmable Electronic, Semi- Resonant, Rapid Start, or Switched Start.
Features Surface Mount Device Technology, high quality Glass Fibre Printed Circuit Board, including a Solder Mask to resist moisture and resultant short circuiting.
Extremely robust Extruded Anodized Aluminium Housing – no rust, and difficult to flatten.
Smallest profile for currently available Inverters, 31mm high x 40 mm wide. Standard length of 208mm.
Proven design – has now been produced for 10 years, with ongoing refinement and improvements to the initial design.
The Inverter can operate in the Maintained, Non-Maintained, or Sustained Mode.
High Frequency, High Voltage Output, allowing for greater efficiency and smaller physical size.
Capable of running more than one lamp in the Maintained and Non-Maintained Modes. (See 105 D2X or 105 P2X Series.)can we do a 106f2x etc? is there a need?
Lightweight 310 Grams.
Economical. Current consumption under Normal Conditions is a modest 50mA. (0.050 Amp.)
Low Voltage Shutoff, to protect against deep discharge of the External DC Power Source.
Mains Voltage Tolerance is ± 10% at 230 V AC, 50/60 Hz.
Simply put, good quality, reliable, and economically priced.
Suitably suppressed against causing mains interference (EMI.)
Inverters for other External DC Power Sources are also available. (See INVERTER 112 F, INVERTER 124 F, INVERTER 148 F, INVERTER 1110 F, INVERTER 1220 F.) These Inverters are physically identical to the above Inverters, and are based on the same Inverter Design Principals, and therefore are of the same quality and reliability.

 

DIMENSIONS (mm) AND WEIGHTS (KG)

CODE

LENGTH

WIDTH

HEIGHT

WEIGHT

40100

208

40

31

0.310

         
         

LENGTH IS OVERALL LENGTH. FOR FIXING CENTRES, SUBTRACT 8mm ON HOUSED UNIT.

ÉCLAT tm 106F Inverter Specifications (Typical.)

ITEM NO:

DETAILS

VALUES

QTY

UNIT PRICE

1

FLUORESCENT INVERTER 106F.      

2

ÉCLAT CODE. 40100.    

3

Mains Input Voltage. 190-260 V. A.C. 50 / 60 Hz.    

4

Battery Charge Voltage Maximum. External Power Source.    

5

Charger Type. External Power Source.    

6

Battery Shut off Voltage (6V Battery Bank.) 4.5 Volts. DC.    

7

Battery Requirements. 6 V DC.    

8

Battery Discharge Current. 2 A. DC.    

9

Inverter Efficiency. 85%.    

10

Power Delivered To Tube (Battery Voltage=6.0V DC) 10.20 Watts.    

11

Inverter Type. Flyback Switch Mode.    

12

Output Frequency. 35 kHz.    

13

Maximum Operating Temperature Shutoff. 65°C.    

14

Housed In Extruded Anodized Aluminium Housing.      
  Passive Plated End Caps, Screwed In Place.      
  Supplied Complete With Colour Coded Wires.      

15

Length. 208mm.    
  Width. 40mm.    
  Height. 31mm.    

16

Durability Subject To Environmental Conditions. Design Life, 10 years.    

17

All Details Included On Printed Label.      

18

Label Includes Small Wiring Diagram.      

19

Serial Number Included on PCB.      

20

Delivery Time (From Date Of Order.) 4 Weeks.    

21

Guarantee Period. 12 Months. Walk In.

Ea.

 

 

Home ] Up ] [OVA EMERGENCY LIGHTING] [ALTENBURGER] [ECLAT INVERTERS]

Send mail to anthony@eclat.co.za or mwtones@mweb.co.za with questions or comments about this web site.
Copyright © 2005 ECLAT LIGHTING. Telephone: +27 11 868 3779 / +27 11 868 2578. Fax: +27 11 868 2578. Mobile: +27 82 562 9620.
Last modified: July, 2010.
COPYRIGHTS © AND VARIOUS PATENTS SUBSIST IN THE PRODUCTS AND IN THE CONTENT OF THIS WEBSITE. UNAUTHORIZED DUPLICATION OF THE PRODUCTS AND OF THE CONTENT BY ANY MEANS IS STRICTLY PROHIBITED. UNAUTHORIZED DUPLICATION OF ANY PROPRIETY METHODS UTILIZED AND AS DESCRIBED IN THESE PRODUCTS AND THEIR RELATED DOCUMENTS, FOR ANY OTHER THAN OUR OWN INTENDED PURPOSES, IS STRICTLY PROHIBITED. THE CONTENT OF THIS WEBSITE, IT'S PRODUCTS AND IT'S DOCUMENTS ARE STRICTLY PRIVATE AND CONFIDENTIAL, AND SHALL UNDER NO CIRCUMSTANCES BE DISCLOSED TO ANY UNAUTHORIZED THIRD PARTIES, WITHOUT PRIOR AUTHORIZATION FROM THE WRITER. PERMISSION FOR SUCH DISCLOSURE AND/OR DUPLICATION OF THESE PRODUCTS AND THESE DOCUMENTS SHALL BE APPLIED FOR, AND CONFIRMED IN WRITING. FAILURE TO FOLLOW THE ABOVE, WILL RESULT IN CIVIL AND CRIMINAL PROSECUTION.

ALL ITEMS MARKED IN RED, ARE NOT YET VERIFIED / ARE FUTURE PROJECTS / ARE IN PROGRESS.

ALL PAGES SUBJECT TO CHANGE AND TECHNICAL ERROR.