ÉCLAT INVERTER 150P NM

 

The éCLAT 150P NM (1 = 1 Hour 50 = 50 Watt P = Lead Acid Battery or 12 V DC Power Source NM = Non-Maintained Emergency) Inverter is a robust Inverter which operates in the Non-Maintained Emergency Mode.  The current consumption is in the order of 4A DC and is suitable for operation off a 12 Volt DC Power Supply, offering a Nominal Duration of 1 Hour, or for as Long as the External DC Power Source is Available, and is suitable for operating 5W - 50W Low Voltage Halogen or Low Voltage Incandescent Lamps. Duration is dependent on the Lamp in use. A single 12V, 50W Halogen Lamp will run at 100% Light Output for 1,5 Hours, off a Single 12V 7.2Ah Lead Acid Battery Pack. (See VALID COMBINATIONS)

 

ÉCLAT '150' TYPE INVERTER STANDARD FEATURES: -


The Charger (which forms part of the Inverter Circuitry) and Inverter’s Electronic components are mounted onto a 3mm thick Aluminium Base Plate, which also serves as a Heatsink for dissipation, and for mounting purposes.

The Electronic Control Circuitry of the Inverter ensures optimum Charging Levels, which allows a Full Charge of the relevant Battery Pack to be reached within 24 hours.

Constant Light Output over entire Emergency Duration, except for the last few minutes - approximately 5 minutes. (Light Output Test Reports are available.)
Mains Presence / Charge Indicator LED.
Supplied Complete with Colour Coded Wires for faster installation.
Robust, Mill Finish Aluminium Base Plate.
Low Profile: 75mm x 80mm x 100mm. H x W x L. (150P NM.)
Quality Electronic Components.
Glass Fibre Printed Circuit Board (PCB.)
Solder Mask is a Feature on all Inverters, which assists in preventing Short Circuits and resultant Inverter failure in damp, corrosive or wet environments.
The Electronic Control Circuitry also prevents Deep Discharge and Overcharging of the Hermetically Sealed Lead-Acid Battery, by monitoring Upper and Lower Voltage Levels of the Battery, and thereby ensuring a long Service Life.
Mains Voltage Surge Protection.
Nominal Mains Input Voltage 230V A.C. 50 Hz ± 10%.
Failure Rate of less than 0.65%.
Design Life of 10 Years.
Inspection and Test Procedures are carried out TWICE on EACH and EVERY Inverter to ensure it’s Functionality. Full Test and Inspection procedure is available.
Light Output Tests (under a controlled environment) are carried out on a regular basis, to ensure that all Inverters conform to the set requirements.
In the Maintained Mode, One Type of Inverter is all that is required, to cater for all Types of Standard Control Gear, be this: -
Conventional Magnetic / Wire Wound Transformers, Electronic Transformers, Dimmable Electronic Transformers (from any Manufacturer.) Please inquire for suitable Wiring Diagrams.
The Inverter can accommodate all of these Variations, Provided that the Inverter, under Emergency Conditions, Powers a Quantity of Lamps which does not exceed the Maximum Output Power Rating.

 

ÉCLAT INVERTER ADDITIONAL FEATURES: -
 

Inverters can be Resin Cast for Rugged Environments.
Data / Specification Sheets are available for each Inverter (except for the new products) should You require.
Can be combined with the ECLAT Self Diagnostic System (SDS) to allow for periodic Functional and Duration Tests. (See SDS.)

 

ADVANTAGES OF ÉCLAT INVERTERS: -
 

Light output remains constant over the entire Duration Period, irrespective of the lamp wattage, and irrespective of the Standard Control Gear used.
Not limited to a specific Ampere Hour rating of External Power Source for a given Inverter.
Simple wiring of Inverters.
In the Maintained Emergency Mode, the Inverter will accommodate Conventional Magnetic / Wire Wound Transformers, Electronic Transformers, Dimmable Electronic Transformers (from any Manufacturer.)
Features Quality Electronic Components, high quality Glass Fibre Printed Circuit Board, including a Solder Mask to resist moisture and resultant short circuiting.
Extremely robust Aluminium Base Plate  – no rust and difficult to damage.
Low Profile: 75mm x 80mm x 100mm. H x W x L. (150P NM.)
Proven design – has now been produced for 20 years, with ongoing refinement and improvements to the initial design.
The Inverter can operate in the Maintained, Non-Maintained, or Sustained Mode when equipped with the correct additional Circuitry. (See INVERTER 150P M.)
High efficiency and small physical size.
The 150 P NM is capable of running more than one lamp in the Non-Maintained Emergency Mode.
Lightweight 750 Grams.
Economical. Current consumption under Normal Conditions is a modest 50mA. (0.050 Amp.)
Low Voltage Shutoff, to protect against deep discharge of the Battery or External DC Power Source.
Mains Voltage Tolerance is ± 10% at 230 V AC, 50/60 Hz.
Simply put, good quality, reliable, and economically priced.
The INVERTER 150P M. Inverters are physically identical to the above Inverter, and is based on the same Inverter Design Principals, and therefore are of the same quality and reliability.

 

DIMENSIONS (mm) AND WEIGHTS (KG)

CODE

LENGTH

WIDTH

HEIGHT

WEIGHT

40255

100

80

75

0.750

         
         

LENGTH IS OVERALL LENGTH. FIXING CENTRES, 65mm ALONG LENGTH OF HOUSING.

ÉCLAT tm 150P NM Inverter Specifications (Typical.)

ITEM NO:

DETAILS

VALUES

QTY

UNIT PRICE

1

FLUORESCENT INVERTER 150P NM.      

2

ECLAT CODE 40255.    

3

Mains Input Voltage. 190-260 V. AC. 50Hz.    

4

Mode Of Operation. Non-Maintained.    

5

Battery Charge Voltage Maximum. 13.8 Volts D.C.    

6

Charger Type. Constant Voltage.    

7

Battery Shut off Voltage (12V 7,2 Ah Pb Battery Pack.) 9.0 Volts. DC.    

8

Number of Battery Cells Required (4 - 7.2Ah Pb.) 1 x 12 V DC or 2 x 6V DC.    

9

Battery Discharge Current. 3.8 A. DC.    

10

Inverter Efficiency. 85%.    

11

Power Delivered To Lamp (Battery Voltage=13.0VDC) 41.99 Watts.    

12

Suitable for the following 12 V Halogen / Incandescent Lamps: - 5 x 10W, 3 x 15W, 2 x 20W, 1 x 35W, 1 x 50W.    

13

Inverter Type. D.C.    

14

Output Frequency. 0 Hz.    

15

Maximum Operating Temperature Shutoff. 55°C.    

16

No Housing, Open Board Construction.      

17

Length. 100mm.    
  Width. 80mm.    
  Height. 75mm.    

18

Durability Subject to Environmental Conditions. Design Life, 10 Years.    

19

All Details Included On Printed Circuit Board.      

20

Serial Number Included On Printed Circuit Board.      

21

Delivery Time (From Date Of Order.) 4 Weeks.    

22

Guarantee Period. 12 Months. Walk In.

Ea.

 

 

Home ] Up ] [OVA EMERGENCY LIGHTING] [ALTENBURGER] [ECLAT INVERTERS]

Send mail to anthony@eclat.co.za or mwtones@mweb.co.za with questions or comments about this web site.
Copyright © 2005 ECLAT LIGHTING. Telephone: +27 11 868 3779 / +27 11 868 2578. Fax: +27 11 868 2578. Mobile: +27 82 562 9620.
Last modified: July, 2010.
COPYRIGHTS © AND VARIOUS PATENTS SUBSIST IN THE PRODUCTS AND IN THE CONTENT OF THIS WEBSITE. UNAUTHORIZED DUPLICATION OF THE PRODUCTS AND OF THE CONTENT BY ANY MEANS IS STRICTLY PROHIBITED. UNAUTHORIZED DUPLICATION OF ANY PROPRIETY METHODS UTILIZED AND AS DESCRIBED IN THESE PRODUCTS AND THEIR RELATED DOCUMENTS, FOR ANY OTHER THAN OUR OWN INTENDED PURPOSES, IS STRICTLY PROHIBITED. THE CONTENT OF THIS WEBSITE, IT'S PRODUCTS AND IT'S DOCUMENTS ARE STRICTLY PRIVATE AND CONFIDENTIAL, AND SHALL UNDER NO CIRCUMSTANCES BE DISCLOSED TO ANY UNAUTHORIZED THIRD PARTIES, WITHOUT PRIOR AUTHORIZATION FROM THE WRITER. PERMISSION FOR SUCH DISCLOSURE AND/OR DUPLICATION OF THESE PRODUCTS AND THESE DOCUMENTS SHALL BE APPLIED FOR, AND CONFIRMED IN WRITING. FAILURE TO FOLLOW THE ABOVE, WILL RESULT IN CIVIL AND CRIMINAL PROSECUTION.