ÉCLAT INVERTER ÉCLATRONIC HID 80P

 

The ÉCLATRONIC HID 80P (HID = High Intensity Discharge Lamps, 80 = 80 Watt, 18 Cell (18 Volt) P = Lead Acid Battery) Inverter is a Small but robust Inverter which operates in the Maintained Mode. The current consumption is in the order of 4.5A DC and is suitable for operation off 3 pieces, 6V, 4.5Ah Lead Acid Cells, offering a Duration of 1 Hour, and is suitable for operating 80W HID Lamps (High Intensity Discharge Lamps.) Light Output is dependent on the Lamp in use. A 80W Lamp will run at 100% Light Output. (See VALID COMBINATIONS)

 

ÉCLAT INVERTER ÉCLATRONIC HID STANDARD FEATURES: -
 

Constant Light Output over entire Emergency Duration, except for the last few minutes - approximately 5 minutes. (Light Output Test Reports are available.)
Mains Presence / Charge Indicating LED.
Supplied Complete with Colour Coded Wires for faster installation.
Robust, Mill Finish Extruded Aluminium Housing.
Low Profile: 31mm x 40mm x 280mm. H x W x L. (HID 80P.)
Surface Mount Technology (SMT) Electronic Components.
Glass Fibre Printed Circuit Board (PCB.)
Solder Mask is a Feature on all Inverters, which assists in preventing Short Circuits and resultant Inverter failure in damp, corrosive or wet environments.
Battery Low Voltage Cut-off Protection.
Battery Over Voltage Charge Protection.
In the Case of Lead Acid Batteries, the Charger Shuts off, until Battery requires topping up.
Mains Voltage Surge Protection.
Nominal Mains Input Voltage 230V A.C. 50 Hz ± 10%.
Failure Rate of less than 0.65%.
Design Life of 10 Years.
Inspection and Test Procedures are carried out TWICE on EACH and EVERY Inverter to ensure it’s Functionality. Full Test and Inspection procedure is available.
Light Output Tests (under a controlled environment) are carried out on a regular basis, to ensure that all Inverters conform to the set requirements.
One Type of Inverter is all that is required, to cater for all Types of Standard Control Gear, be this: -
Switched Start, Semi-Resonant, Rapid Start, Electronic, Dimmable Electronic (from any Manufacturer.) Please inquire for suitable Wiring Diagrams.

ÉCLAT INVERTER ÉCLATRONIC HID ADDITIONAL FEATURES: -
 

Inverters can be Resin Cast for Rugged Environments.
Can be Combined with a Suitable Battery within a Single Housing.
Data / Specification Sheets are available for each Inverter (except for the new products) should You require.
Can be combined with the ÉCLAT Self Diagnostic System (SDS) to allow for periodic Functional and Duration Tests. (See SDS.)

Unique Patent Protected Mode of Operation. Patent No: 2000/2245.

 

ADVANTAGES OF ÉCLAT INVERTERS: -
 

Not limited to a specific number of cells for a given Inverter.
Light output remains constant over the entire Duration Period, irrespective of the lamp wattage, and irrespective of the Standard Control Gear used.
Not limited to a specific Ampere Hour rating of Lead Acid Cells for a given Inverter.
Simple wiring of Inverters.
In it’s Standard form, the Inverter will accommodate any type of Ballast, be they - Electronic, Dimmable Electronic, Semi- Resonant, Rapid Start, or Switched Start.
Features Surface Mount Device Technology, high quality Glass Fibre Printed Circuit Board, including a Solder Mask to resist moisture and resultant short circuiting.
Extremely robust Extruded Anodized Aluminium Housing – no rust, and difficult to flatten.
Smallest profile for currently available Inverters, 31mm high x 40 mm wide. Standard length of 280mm.
Proven design – has now been produced for 10 years, with ongoing refinement and improvements to the initial design.
The Inverter can operate in the Maintained, Non-Maintained, or Sustained Mode.
High Frequency, High Voltage Output, allowing for greater efficiency and smaller physical size.
Lightweight 450 Grams.
Economical. Current consumption under Normal Charging Conditions is a modest 200mA. (0.20 Amp.)
Low Voltage Shutoff, to protect against deep discharge of the Battery Pack.
Mains Voltage Tolerance is ± 10% at 230 V AC, 50/60 Hz.
Simply put, good quality, reliable, and economically priced.
Suitably suppressed against causing mains interference (EMI.)
The NiCad Inverters (See INVERTER 80 D) are physically identical to the Lead Acid Inverters, and are based on the same Inverter Design Principals, and therefore are of the same quality and reliability.

 

DIMENSIONS (mm) AND WEIGHTS (KG)

CODE

LENGTH

WIDTH

HEIGHT

WEIGHT

40520

280

40

31

0.450

         
         

LENGTH IS OVERALL LENGTH. FOR FIXING CENTRES, SUBTRACT 8mm ON HOUSED UNIT.

 

ÉCLAT tm  ÉCLATRONIC HID 80 P Inverter Specifications (Typical.)

ITEM NO:

DETAILS

VALUES

QTY

UNIT PRICE

1

HID INVERTER 80 P.      

2

ÉCLAT CODE. 40510.    

3

Mains Input Voltage. 190-260 V. AC. 50 / 60 Hz.    

4

Battery Charge Voltage Maximum. 21.0 Volts D.C.    

5

Charger Type. Constant Voltage.    

6

Battery Shut off Voltage (18V 4 Ah Pb Battery Pack.) 13.5 Volts D.C.    

7

Number of Battery Cells Required (4.5 - 7.2Ah Pb.) 3 x 6V DC.    

8

Battery Discharge Current. 4.5A. DC.    

9

Inverter Efficiency. 85%.    

10

Power Delivered To Tube (Battery Voltage=19.5V DC) 74.588 Watts.    

11

Inverter Type. Flyback Switch Mode.    

12

Output Frequency. 35 kHz.    

13

Maximum Operating Temperature Shutoff. 65°C.    

14

Housed In Extruded Anodized Aluminium Housing.      
  Passive Plated End Caps, Screwed In Place.      
  Supplied Complete With Colour Coded Wires.      

15

Length. 280mm.    
  Width. 40mm.    
  Height. 31mm.    

16

Durability Subject To Environmental Conditions. Design Life, 10 years.    

17

All Details Included On Printed Label.      

18

Label Includes Small Wiring Diagram.      

19

Serial Number Included on Printed Circuit Board.

     

20

Delivery Time (From Date Of Order). 4 Weeks.    

21

Guarantee Period. 12 Months. Walk in.

Ea.

 

 

Home ] Up ] [OVA EMERGENCY LIGHTING] [ALTENBURGER] [ECLAT INVERTERS]

Send mail to anthony@eclat.co.za or mwtones@mweb.co.za with questions or comments about this web site.
Copyright © 2005 ECLAT LIGHTING. Telephone: +27 11 868 3779 / +27 11 868 2578. Fax: +27 11 868 2578. Mobile: +27 82 562 9620.
Last modified: July, 2010.
COPYRIGHTS © AND VARIOUS PATENTS SUBSIST IN THE PRODUCTS AND IN THE CONTENT OF THIS WEBSITE. UNAUTHORIZED DUPLICATION OF THE PRODUCTS AND OF THE CONTENT BY ANY MEANS IS STRICTLY PROHIBITED. UNAUTHORIZED DUPLICATION OF ANY PROPRIETY METHODS UTILIZED AND AS DESCRIBED IN THESE PRODUCTS AND THEIR RELATED DOCUMENTS, FOR ANY OTHER THAN OUR OWN INTENDED PURPOSES, IS STRICTLY PROHIBITED. THE CONTENT OF THIS WEBSITE, IT'S PRODUCTS AND IT'S DOCUMENTS ARE STRICTLY PRIVATE AND CONFIDENTIAL, AND SHALL UNDER NO CIRCUMSTANCES BE DISCLOSED TO ANY UNAUTHORIZED THIRD PARTIES, WITHOUT PRIOR AUTHORIZATION FROM THE WRITER. PERMISSION FOR SUCH DISCLOSURE AND/OR DUPLICATION OF THESE PRODUCTS AND THESE DOCUMENTS SHALL BE APPLIED FOR, AND CONFIRMED IN WRITING. FAILURE TO FOLLOW THE ABOVE, WILL RESULT IN CIVIL AND CRIMINAL PROSECUTION.

ALL ITEMS MARKED IN RED, ARE NOT YET VERIFIED / ARE FUTURE PROJECTS / ARE IN PROGRESS.

ALL PAGES SUBJECT TO CHANGE AND TECHNICAL ERROR.